background image
C H A P T E R 2 3
Endpoint Interface
Using the Endpoint Interface
23-15
termination sequence, or an array of items, any one of which will cause the input to
terminate. A termination sequence can be a single character, a string, a number, or
an array of bytes. If you don't want to look for a termination sequence, don't define
this slot.
For the
'binary
data form, you cannot use the
endSequence
slot to specify a
termination condition.
Note
Note that the system executes byte-by-byte comparisons between
the termination sequence and the input stream. To facilitate this
process, the termination sequence (or elements within the
endSequence
array) is converted to a byte or binary format to
speed the comparison. Internally, single characters are converted
to single bytes using the translation table specified by the
endpoint
encoding
slot. Numbers are converted to single bytes;
strings are converted to binary objects. An array of bytes is also
treated as a binary object. For large numbers, you must encode
your number as an array of bytes if there are significant digits
beyond the high order byte of the number.
If you want to terminate input based on a transport-level end-of-packet (EOP)
indicator, then you can set the
useEOP
slot in the
termination
frame. This slot
holds a Boolean value specifying whether or not to look for EOP indicators.
Specify this slot only if the input spec
rcvFlags
slot includes the
kPacket
flag.
Moreover, if the
rcvFlags
slot includes the
kPacket
flag and you do not specify
the
termination.useEOP
slot, the system effectively sets
useEOP
to the
default value
true
. For more information, see the following section, "Specifying
Flags for Receiving."
It is not appropriate to specify the
termination
slot for data forms other than
'string
,
'bytes
, and
'binary
. The
'char
and
'number
data forms
automatically terminate after 1 and 4 bytes, respectively. The
'frame
data form is
terminated automatically when a complete frame has been received, and the
'template
data form terminates when the number of bytes received matches the
typelist
specification in the
target
frame.
To limit the amount of accumulated data in the input buffer, you can define a
discardAfter
slot in the input spec. You can do this only when you have not
specified a
termination.byteCount
slot for
'string
and
'bytes
data
forms. The
discardAfter
slot sets the input buffer size. If the buffer overflows,
older bytes are discarded in favor of more recently received bytes.
© 2007-2024, o7 studio » при воспроизведении материала сайта ссылка обязательна